automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense
®
regularly measures the operating temperature
and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70/60,000 hour lumen
maintenance curves. LEDSense
®
is always active, and will compensate for variation in thermal
conditions due to heatsinking, ambient air, engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense
®
Power Curve identifies the
reduction in input power over temperature.
0%!
10%!
20%!
30%!
40%!
50%!
60%!
70%!
80%!
90%!
100%!
110%!
25! 30! 35! 40! 45! 50! 55! 60! 65! 70! 75! 80!
% of initial LOP
Heatsink Temperature Tc [°C]
Light Output vs Temperature
0%!
10%!
20%!
30%!
40%!
50%!
60%!
70%!
80%!
90%!
100%!
110%!
25! 30! 35! 40! 45! 50! 55! 60! 65! 70! 75! 80!
% of initial Power
Heatsink Temperature Tc [°C]
Power vs. Heatsink Temperature